Agilent-Keysight 8593E

Spectrum Analyzer, 9kHz-22GHz

The 8590 Series offers a wide range of performance, features, and optional capability to meet your measurement needs. Standard models offer RBW from 1 kHz to 3 MHz and amplitude as low as -115 dBm to +30 dBm, optionally down to 30 Hz RBW & -130 dBm. One-button measurement routines include FFT, ACP and TOI. Optional personality cards support applications like CATV, component test, EMC, lightwave, and wireless communications.

Available instrument options include HP-IB or RS-232 ports with a parallel printer port, tracking generator, narrow RBW, time-gated spectrum analysis, AM/FM demod, quasi-peak detector, digital demod, and more. .

Options:
004 - Precision frequency reference
009 - Local oscillator and sweep + tune outputs (rear panel)
010 - Built-in tracking generator, 50 Ohm (9 kHz-2.9 GHz)
012 - DECT source
015 - Protective soft tan carrying/operating case
016 - Protective soft yellow operating/carrying case
026 - Frequency extension to 26.5 GHz (APC 3.5 mm connector)
027 - Frequency extension to 26.5 GHz (type-N connector)
040 - Front panel protective cover w/CRT viewing hood
041 - HP-IB interface and parallel printer interface
042 - Protective soft carrying case/backpack
043 - RS-232 interface and parallel printer interface
050 - Improved amplitude accuracy for NADC-TDMA/PCS bands
051 - Improved amplitude accuracy for PDC bands
052 - Improved amplitude accuracy for PHS band
053 - Improved amplitude accuracy for CDMA/PCS bands
101 - Fast time-domain sweeps and Analog + display
102 - AM/FM demod. with speaker and TV sync. trigger
103 - Quasi-peak detector and AM/FM demod with speaker
105 - Time-gated spectrum analysis
107 - TV receiver video tester
110 - CT2 demodulator
111 - Group delay w/compatible tracking generator
112 - DECT demodulator
119 - Noise figure
130 - Narrow resolution bandwidths (30 Hz,100 Hz,300 Hz and 200 Hz EMI)
140 - Narrow resolution bandwidths/precision frequency reference (Opt 004 and 130)
151 - DSP, fast ADC, and digital demodulator
160 - PDC, PHS, NADC, and CDMA firmware for Option 151
163 - GSM900/DCS1800 firmware for Option 151
180 - TV picture on screen (NTSC, PAL, and SECAM)
301 - TV sync. trigger capability, fast time domain sweeps, AM/FM demodulator, and Analog + display (Option 101 and 102)
711 - 50/75 Ohm matching pad with 100V DC block
908 - Rack mount kit without handles
909 - Rack mount kit with handles
910 - Additional user's guide, calibration guide, and quick reference guide
915 - Component level information and service guide
AB_ - Quick reference guide in local languages
B70 - BenchLink spectrum analyzer
BD0 - Code division multiple access
BD1 - Global system for mobile communication
BD2 - North american digital cellular system
BD3 - Pacific digital cellular system
BD4 - Personal handyphone system
K10 - Built-in tracking generator, 50 Ohm (9 kHz to 2.9 GHz)
R01 - Fast time-domain sweeps and analog + display
R02 - AM/FM demodulator with speaker and TV sync trigger circuitry
R04 - Precision frequency reference
R05 - CT2 demodulator
R06 - DECT demodulator
R07/R17 - TV receiver/ video tester
R15 - Time-gated spectrum analysis
R16 - Protective soft yellow operating/carrying case
R19 - Noise figure
R21 - HP-IB interface
R23 - RS-232 interface
R24 - Parallel printer interface
R25 - Protective soft tan operating/carrying case
R30 - Narrow resolution bandwidths
R41 - HP-IB interface and parallel printer interface
R43 - RS-232 interface and parallel printer interface
R50 - Improved amplitude accuracy for NADC-TDMA/PCS bands
R51 - Improved amplitude accuracy for PDC bands
R52 - Improved amplitude accuracy for PHS band
R53 - Improved amplitude accuracy for CDMA/PCS cellular bands
R60 - PDC, PHS, NADC, and CDMA firmware for Option 151
R63 - GSM900/DCS1800 firmware for Option 151
R70 - PDC/PHS/NADC/CDMA FW+Opt 151 retro. kit
R73 - DSP, fast ADC, and digital demodulator with GSM900/DCS1800 firmware
R80 - TV picture on screen (NTSC, PAL, and SECAM)
UK6 - Commercial calibration certificate with test data
W30 - Two additional years return-to-HP service
W32 - Two additional years return-to-HP calibration
W34 - 3 year standards compliant calibration service
W50 - Four additional years return-to-HP service
W52 - Four additional years return-to-HP calibration
W54 - 5 year standards compliant calibration service
0B0 - Delete manual set
0Q8 - Factory service training
- See more at: https://www.testequipmentconnection.com/3022/Agilent_8593E.php#sthash.xp8bwWPN.dpuf

Company Information:

The Worlds Largest Distributor of New, Refurbished, and Second Hand Electronic Test and Measurement (T&M) Equipment.

Lake Mary, Florida, USA

Equipment Dealer / Broker / Auctions, Manufacturer

  • Phone 407-804-1299
  • Fax 407-804-1277

See Supplier Website »

Company Postings:

(3842) used SMT equipment marketplace items

(69) products in the catalog

(26) news releases

SMT Equipment & PCB Assembly Machines RFQ

This Agilent 8593E has been added in 16 Dec 2015

This Agilent 8593E has been viewed 465 times.

One stop service for all SMT and PCB needs

Fluid Dispensing, Staking, TIM, Solder Paste