Aeroflex GPS-101-2
Model: |
Aeroflex GPS-101-2 |
Category: |
|
Model Year: |
2009 |
Condition: |
|
Location: |
Florida, USA |
Offered by: |
|
Contact Supplier |
Aeroflex IFR GPS-101-2
IFR Aeroflex GPS-101-2 Global Positioning Simulator with the RF Antenna Coupler
The GPS-101-2 Global Positioning Simulator provides for installation and functional bench testing of global positioning system (GPS) receivers.
The GPS-101-2 simulates one of many specific global positioning satellites. Selected specific satellite vehicle (SV) signals transmitted with selected navigation (NAV) data test patterns are used to verify the operational integrity of GPS receivers.
Generator Specifications:
Frequency: 1575.42 MHz
Accuracy: Same as Timebase
Doppler Offset (Selectable): +3.936 or -3.935 kHz
Accuracy: Same as Timebase
Channels: Single SV simulation (selectable 1 to 37)
Phase Modulation: BPSK
PRN Code (C/A Code): C/A Code = 1.023 MHz, 1023 bit gold code
NAV Data (Test Pattern): 50 Hz
Output: RF Out Connector
Level: -145 to -85 dBm
Steps: 1 dB
Accuracy (into 50 Ohms): 2 dB (ac coupled)
Spurious: < -40 dBc over the 20 MHz bandwidth
External Modulation:
Input: AUX I/O Connector
Level (TTL): Vih = >2 V at 1 MicroA, Vil = <0.8 V at 1 mA
Timebase Specifications:
Standard:
Frequency: 10 MHz
Uncertainty: 1 ppm
Temperature Stability: 1 ppm
Aging Rate: 1 ppm/yr, 5 ppm/10 years
External Reference:
Input: EXT REF IN Connector
Frequency: 10.0 MHz
Level: 0.25 to 6.0 Vp-p
Impedance: 150 Ohms nominal
Output: EXT REF OUT Connector
Frequency: 10.0 MHz nominal
Level: 1 Vp-p nominal into 50 Ohms
Antenna Coupler Specifications:
Coupling: -20 dB typical at 1575.42 MHz (assumes 4.77 dB patch antenna gain and 4 dB cable)
Isolation: >25 dB at 1575.42 MHz (30 dB typical)
Power Requirement Specifications:
AC Requirements:
Source Voltage and Frequency: 100 to 120 VAC, 60 Hz or 220 to 240 VAC, 50 Hz
Power Consumption: 20 W maximum, 13 W nominal at 115 VAC, 8 W nominal at 230 VAC
Battery:
Operation Time: > or = to 2 hours, 6 hours typical)
Full Charge Time:
Unit Operating: < or = to 8 hours at 115 VAC, 60 Hz
Unit Not Operating: < or = to 6 hours at 115 VVAC, 60 Hz
- See more at: http://www.testequipmentconnection.com/41270/Aeroflex_IFR_GPS-101-2.php#sthash.DymSwkSd.dpuf