70KV 2mA Negative X-ray tube power supply
Company Information:
Name: |
70KV 2mA Negative X-ray tube power supply |
Offered by: |
|
70KV 2mA Negative X-ray tube power supply Description:
Product Name XFL
Power(W) 75W-200W,
Output Voltage(KV) ,20,25,30,35,40,50,60,65,70,80,90,100,120,125,130,150,160,
Wisman's XFL Series of regulated X-ray power supplies offer output voltages to130kV and incorporate a filament supply which provides regulated AC current adjustable between 0.3A and 5A at 0-10V.High voltage and filamentcurrent can be linearly ramped up. The XFL incorporates local and remote programming,monitoring,safety interlock,short-circuit and overload protection.
TYPICAL APPLICATIONS:
Plastics Sorting, Crystal Inspection,Plating Measurement ,Diamond Inspection,Mineral Analysis,X-Ray Fluorescence,X-Ray Diffraction.
OPTIONS:
LR(X) Low Ripple 0.25%、0.006%、0.003% 、0.001%
USB USB2.0 Interface
RS232 RS-232 Interface
RS422 RS-422 Interface
DC60 Input +60Vdc±10%, 5.0A
SPECIFICATIONS:
Input: +48Vdc±10%, 6.25A maximum.
Output: 0 to 160kV at 0 to 2 mA,limited to a maximum of 200watts.
Voltage Control:
Local: Internal multi-turn potentiometer to set voltage
from 0 to full output voltage.
Remote: 0 to +10Vdc proportional from 0 to full output
voltage.
Accuracy: ±1%. ZIN: 10Mohm.
Emission Control:
Local: Internal potentiometer to set beam current between 0 and full output.
Remote: 0 to +10Vdc proportional from 0 to full output
current. Accuracy : ±1%. ZIN: 10Mohm.
AC Filament Supply:
Current: 0-5A, adjustable Voltage: 0-10V
Voltage Regulation:
Load: 0.01% of output voltage no load to full load.
Line: ±0.01% for ±10% change in input voltage.
Current Regulation:
Load: 0.01% of output current from 0 to rated voltage.
Line: ±0.01% for ±10% change in input voltage.
Ripple:
0.1% p-p of output voltage.
Temperature Range:
0℃to +50℃ operational
Temperature Coefficient:
25ppm/ ℃, voltage or current regulated.
Stability:
≤25ppm/hr after 1/2 hour warm-up.
Voltage and Current Monitors:
0 to +10Vdc proportional from 0 to rated output.Accuracy ±1%.
Cooling:
Free convection for P≤100W, Fan (30CFM) assisted
for P>120W,except 40KV。
Dimensions:
1-40KV: L:166mm,W:120mm,D:120mm;
50-70KV:L:230mm,W:100mm,D:140mm;
80-100KV:L:405mm,W:190mm,D:155mm;
110-130KV:L:460mm,W:210mm,D:175mm;
140-160KV:L:515mm,W:230mm,D:195mm。