Electronics Forum | Sat Sep 08 16:02:44 EDT 2012 | processman
hi, We have a strange issue with a DEK 265 Lt, it powers up and initialises fine. Camera LED`s flash, cognex card intitialises with no error. The issue is we have no fiducial recognition or image on the monitor. Have swapped out camera, cogn
Electronics Forum | Mon Nov 30 12:29:17 EST 2015 | james1903
Are there any Siplace users out there that have any experience of the latest "smart feeders" for X series (version 3 I think, with built in handle and LED´s instead of LCD display) I am specifically interested to get input on any issues experienced w
Electronics Forum | Mon Jan 27 12:02:00 EST 2003 | Mike Konrad
Dave is correct. No-clean flux + water = white residue (unless the proper chemical is mixed with the water). Additionally, no-clean flux + IPA = white residue. Many saponifiers work well as do other cleaning agents. White residue may also be a re
Electronics Forum | Wed Sep 25 09:59:44 EDT 2013 | bobpan
Hello, This is from my old documents....hope it helps. I would first try mod code 53 = 2 first.....if the machine is a 2C. The motor was known for causing this problem after getting old. These are all resolutions for motor error 4. Step Potential P
Electronics Forum | Tue Aug 15 07:02:13 EDT 2000 | George Verboven
We are assembling SMD-Leds (Chip LED cl-220yg-c-ts)on flex foil with Electrical conductive glue (Matthey A1401). When we investigated these foils we found cracks between the conductive adhesive and round the edge of the Chip-leds. This cracks cause f
Electronics Forum | Tue Nov 15 19:31:54 EST 2005 | eeltec
>I/OPERATION ==> >1/RUNNING ==> but any command that I try gives an E100 error and in the left side of the monitor a square with: Conditions Initialized Waiting Emg stop (in red) org incmp (in red) Interlock (in red) data comp Use Vac
Electronics Forum | Thu Mar 14 09:07:26 EST 2002 | cfraser
I can not tell you what the actual stress limits are. I can tell you that de-paneling PCB's by hand is a very poor choice. I have seen numerous accounts of cracked caps, resistors, and LED�s due to incorrect de-paneling procedures. I would recommend
Electronics Forum | Mon Mar 06 11:13:08 EST 2006 | fredericksr
I ran this same process by MyData when I was there for training and I received the message that calibrating the force sensor through the service menu was an invalid technique. Correct me if I am wrong, but every tool should recalibrate itself when i
Electronics Forum | Wed Feb 14 08:48:57 EST 2024 | andrii
hi, I have very very old DEK 265 Lt And I have a problem that Mr. processman described a long time ago. But no one answered him. Maybe someone can help me now? "We have a strange issue with a DEK 265 Lt, it powers up and initialises fine. Camera LE
Electronics Forum | Fri Nov 03 11:36:34 EST 2006 | mika
Hi, It is good news to "hear" that You found the problem. This control board has also broken for us once but we had a broken camera unit from where we took this board as a replacement. Unfortunately I was not able to find the circuit diagram (among a