Humidity of SMT component storage environment.

Electronics Forum | Sat Jan 20 20:54:03 EST 2001 | fmonette

Dear Mike, As you might have noticed from the labels on the dry bags, the maximum floor life is specified by the component manufacturer and it can range from 1 year (level 2) down to a few hours after mandatory bake (level 6). This limit is based o

BGA rework: Coplanarity of Xilinx before and after reflow.

Electronics Forum | Tue May 17 08:00:26 EDT 2005 | Bob R.

We went through this with one PBGA supplier recently and they were able to get the problem under control by fixing some of their molding processes that were inducing residual stresses. You can really see it in a thermal moire where you measure warpa

Re: How to qualify the solder flux of a new vendor?

Electronics Forum | Wed Nov 17 11:20:23 EST 1999 | Dave F

Hey Gyver: If you don�t mind (which you don�t have any choice about, because I�m going to do it anyhow, cause it�s MY word processor), I�m going to respond genericly, but still be directed to your question. Much of the following is paraphrased from

Has anyone heard of a no clean paste that can be cleaned in straight DI water ?

Electronics Forum | Tue Jan 30 18:25:25 EST 2018 | aqueous

This is one of the most common questions I get asked. Why clean no-clean flux. It was stated earlier that no-clean residues are benign. This may or may not be accurate. It depends on several factors including the reflow process. In a perfect world, t

Acceptance Criteria Ion Chromatography testing?

Electronics Forum | Wed May 23 10:11:43 EDT 2012 | blnorman

Simple answer is no, there is no universally acknowledged acceptance criteria. Some time ago, I started a spreadsheet with the acceptance levels suggested by various labs on the individual ionic species. All are relatively close in their individual

Re: Ionic testing and No-Clean flux

Electronics Forum | Sat Feb 05 09:08:18 EST 2000 | Dave F

Casimir: Let me expand on something that I said in my response to your thread on ionic testing. Generally, no-clean people don�t use ROSE testing as part of their process control, because the ROSE test is essentially washing your board in DI/IPA �

Re: white residue

Electronics Forum | Wed Jan 27 21:02:53 EST 1999 | Dave F

| i am working with the noclean process and getting white residues on the bottomside of the board probably due to the | wave soldering flux.i am using a no-clean solder paste and a noclean wave solder flux.The boards passed the accelerated temperatu

Re: white residue

Electronics Forum | Thu Jan 28 08:58:10 EST 1999 | Peet

| | i am working with the noclean process and getting white residues on the bottomside of the board probably due to the | | wave soldering flux.i am using a no-clean solder paste and a noclean wave solder flux.The boards passed the accelerated tempe