Electronics Forum | Wed Dec 30 17:34:23 EST 1998 | Michael Allen
I'm afraid we don't agree regarding the best test method to use here. My understanding is as follows. The omegameter test measures board-level, ionic contamination (i.e., average for the entire board area and all components); it does not tell you w
Electronics Forum | Thu Dec 31 01:09:18 EST 1998 | Kelvin Chow
Dear Micheal, SIR test is used to characterize fluxes by determining the degration of electrical insulation resistance of rigid printed wiring board specimens after exposure to the specified flux. (IPC TM-650 #2.6.3.3 http://www.ipc.org/html/tm2.6.h
Electronics Forum | Thu Dec 31 14:20:35 EST 1998 | Michael Allen
Kelvin, Yes, we're referencing the same spec. I performed the test under the Class 2 conditions (except that I used a 100V bias rather than 50V...but my water-washed microBGAs still passed). Regarding the omegameter test: we have this instrument,