Full Site - : mydata my19 (Page 6 of 8)

Mydata Hydra tool reference mark error

Electronics Forum | Wed May 08 10:40:48 EDT 2013 | huske

We have had this problem before, and Phil was pretty close. On the hydra where the vacuum tubes are connected to the tools shafts you should see a red light inside there. this light locates a lazer cut mark on each of the tool shafts, this lets t

MY 19 Issues?

Electronics Forum | Mon Dec 07 09:43:09 EST 2009 | kpm135

Just to throw my two cents in the MY19 could be slower than the other my machines due to the greater distance the head has to travel to pick up and place the components.The longer distance could also account for extra wear and tear on the motors and

Mydata Pick and place

Electronics Forum | Thu May 10 02:57:03 EDT 2001 | kjellman

Hi, Why not have a look at Philips/Assembl�on, their ACM machine is quite nice. It may also bring you down to Flip Chip, 0201 some through hole and odd form placement. Nice options like bulk feeding, coplanarity tests, fluxing for FC, prom feeders (

MY 19 Issues?

Electronics Forum | Sat Dec 05 22:08:21 EST 2009 | casmt

MY9 - 19 are all the same machines. The frame is only bigger. With the 19 you can get up to 256, 8mm feeders if it has the stand table. Ocourse that is an advantatge it can handle large boards with a big table. I have used Mydata a many companys. A

Mydata Hydra tool reference mark error

Electronics Forum | Sat May 04 11:24:08 EDT 2013 | amelby

Hi, I have been having a problem with my My19E's hydra. The machine comes up with an error "Failed to locate HYDRA tool reference marks" and stops running. It does not happen for about the first two hours of running. It starts to happen after that an

My Data

Electronics Forum | Wed Dec 05 22:38:40 EST 2001 | Ivan R

Hello Chris , Well I have work with MYDATA , QUAD and PANASONIC before and now with SIEMENS that is my background to reply to your question . What I can tell you is that MYDATA is the easier machine to fix any equipment breakdowns and that does

MY19 Feeder advance problem slot 2

Electronics Forum | Wed Jun 04 00:28:27 EDT 2008 | chrispy1963

There are a couple of things that you can do. First thing to do is take a flashlight and shine it in the card edge connector of slot 2 and see if a passive component or any other part worked its way into that slot. This will cause multiple leads in