What causes temperature humidity chamber to alarm?
Published: |
December 12, 2019 |
Author: |
climatest symor |
Abstract: |
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.... |
|
|
|
Company Information:
More articles from Symor Instrument Equipment Co.,Ltd »
- Dec 16, 2019 - Factors determine the price of temperature humidity test chamber
- Dec 13, 2019 - Difference between Neutral and Acid Salt Spray Corrosion Test
- Nov 20, 2019 - Why salt spray chamber fail to spray salt mist?
- Nov 17, 2019 - Maintenance and operation of walk-in temperature humidity test chamber
- Nov 15, 2019 - Material Aging Test-UV Weathering Test Chamber
- See all SMT / PCB technical articles from Symor Instrument Equipment Co.,Ltd »
More SMT / PCB assembly technical articles »
- Apr 07, 2026 - Field Trials and Baking Studies of Ultra-Low Asparagine, Genome Edited (CRISPR/Cas9) and Mutant (TILLING) Wheat | SMTnet
- Apr 01, 2026 - Vehicles of change: two exceptional deposits of destroyed chariots or wagons from Late Iron Age Britain | SMTnet
- Mar 17, 2026 - Grey wolf optimization for color quantization | SMTnet
- Mar 17, 2026 - Large Surface‐Rupturing Earthquakes and a >12 kyr, Open Interseismic Interval on the Tintina Fault | SMTnet
- Mar 17, 2026 - Artificial intelligence (AI) applications for marketing: A literature-based study | SMTnet
- Browse Technical Library »
What causes temperature humidity chamber to alarm? article has been viewed 1117 times