Corrosion Resistant Servers for Free-Air Cooling Data Centers

Published:

November 10, 2016

Author:

Qiujiang Liu; Baidu, Inc., Prabjit Singh; IBM

Abstract:

The demand for compute capability is growing rapidly fueling the ever rising consumption of power by data centers the worldwide. This growth in power consumption presents a challenge to data center total cost of ownership. Free-air cooling is one of the industrial trends in reducing power consumption, the power usage effectiveness (PUE) ratio, and the total cost of ownership (TCO). Free-air cooling is a viable approach in many parts of the world where the air is reasonably clean. In Eastern China, the poor quality of air, high in particle and gaseous contamination, is a major obstacle to free-air cooling. Servers exposed to outside air blowing in to data centers will corrode and fail at high rate. The poor reliability of hardware increase TCO dramatically.

This paper describes a corrosion resistant server design suitable for reliable operation in a free-air cooling data center located in Eastern China where the indoor air quality can be as poor as ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) severity level G3. An accelerated corrosion test method of verifying hardware reliability in the ASHRAE severity level G3 environment is also described....

  • Download Corrosion Resistant Servers for Free-Air Cooling Data Centers article
  • To read this article you need to have Adobe PDF installed

You must be a registered user to talk back to us.

 
Company Information:

IBM Corporation

International Business Machines Corporation is a multinational technology. IBM manufactures computer hardware and software, offers infrastructure, hosting and consulting services.

Armonk, New York, USA

Other, Software Manufacturer

  • Phone 800-IBM-4YOU

IBM Corporation website

Company Postings:

(4) technical library articles

(1) news release

  • Jul 27, 2017 - Electrochemical Methods to Measure the Corrosion Potential of Flux Residues | KYZEN Corporation
  • Jul 21, 2017 - How to calibrate JUKI CF feeder | ZK Electronic Technology Co., Limited
  • Jun 01, 2017 - Evaluating the Effects of Plasma Treatment prior to Conformal Coating on Electronic Assemblies to Enhance Conformity of Coverage | Nordson MARCH
  • Mar 30, 2017 - Multiple Methods for Applying Paste Flux or Solder Paste for BGA Rework | BEST Inc.
  • Feb 01, 2017 - BGA Rework Process | BEST Inc.
  • Browse Technical Library »

Corrosion Resistant Servers for Free-Air Cooling Data Centers article has been viewed 724 times

PCB Soldering Tools